WELCOME TO OUR BLOG
We're sharing knowledgein the areas which fascinate us the most
click

Low Letdown Ratio Liquid Colorant for PET Preform Metering

By colorwayglobal November 13th, 2026 8 reviews

Introduction: Low letdown ratio, precise metering, and actual addition percentage are often discussed together, but they describe separate parts of a PET preform coloring trial.

On a PET preform line, low letdown ratio, precise metering, and actual addition percentage are three different numbers. The letdown ratio is the concentration at which the colorant reaches the target shade. Pump output is the setting the operator enters. The actual addition percentage is what the pump delivered relative to the resin processed during a given time. Keeping these numbers separate lets a process engineer trace a shade shift to the colorant, the pump, or the run conditions. It also helps a cost lead see where material is used across a shift.

What Low Letdown Ratio Means in PET Bottle Coloring

Letdown ratio is the amount of colorant added per unit of resin, usually expressed as a ratio or a small percentage. A low letdown ratio means the colorant reaches its target shade with less material per kilo of PET. That result depends on pigment loading in the liquid carrier and on how evenly the pigment is dispersed before it reaches the melt. For a preform plant, the difference appears at quotation: a colorant that develops its shade at a low ratio contributes less mass to the bottle formulation and reduces the liquid volume fed into the injection unit. In polymer coloring, dyes dissolve in the polymer while pigments remain a dispersed solid phase; the way that phase is broken down during melting affects final color. A liquid colorant arrives with pigment already dispersed in a carrier, so the plant's job is to feed it steadily rather than melt and mix a solid concentrate into the resin. This is the practical reason a low addition rate is possible.

1. Low Letdown Ratio Describes How Little Colorant a Shade Needs

Two colorants can produce the same shade at very different ratios, and the ratio alone is separate from which one fits a line. A colorant that starts low but needs extra dosing to clear a streak can use more material than one that starts slightly higher and runs clean from the first shot. The ratio also depends on the resin: viscosity and processing temperature in PET preform injection affect how the liquid carrier moves through the screw. A PET liquid colorant manufacturer will confirm the working ratio range for a given resin and line rather than publish one fixed percentage for every project.

2. Precise Metering Describes How Steadily the Pump Delivers It

Precise metering is the line's ability to hold the chosen ratio shot after shot and hour after hour. It depends on pump calibration, the colorant's flow behavior at line temperature, back pressure at the dosing point, and where that point sits relative to the injection screw. A pump with tight output at the start of a shift can drift as colorant warms in the reservoir, and a line running at full rate can draw more colorant than the same pump delivered during a slow warm-up. Stable metering keeps the actual addition percentage close to plan when throughput changes. That actual addition percentage is what the pump delivered relative to the resin that ran through the machine in the same window. It ties the ratio and pump setting together and is the number a trial record should measure rather than assume.

Why Metering and Dispersion Matter Before the Trial Run

Metering setup and dispersion checks before a trial prevent a bad pump or an unmelted streak from being recorded as a colorant problem. A pump that has not been calibrated against a known liquid weight can report an unreliable percentage when the shade comes out wrong, and the plant may end up chasing the colorant instead of the setup. Before the first shot, answer a few practical questions: Does the pump hold output across the line's normal throughput band, or does it fall off when the machine speeds up? Does the colorant reach the melt before the screw pushes the shot forward? Can flow be verified at the start of a shift without interrupting production? Dispersion checks belong in the same pre-trial window. A short run at the target shade, sampled at the start, middle, and end of an hour, shows whether pigment is spreading evenly through the preform wall or concentrating into streaks. Check preforms in the thin wall as well as the thick section because a shade that looks even in the body can reveal flow lines in the neck or base where shear history changes. Catching that before the full bottle trial avoids a molding cycle of scrap. A plastic colorant manufacturer familiar with PET packaging can help align the pre-trial questions with what a converter needs to see. Both checks cost little compared with a wasted trial and protect the run from being read the wrong way.

How to Read Trial Records for Color Consistency

A trial record for a liquid colorant should separate the colorant, the setup, and the run. The resin lot, colorant lot, and target shade are the anchors. Pump output setting, line speed, melt temperature, and cycle time describe the setup. Sample IDs taken at fixed intervals, plus a color reading or photo for each sample, describe the run. Without all three layers, a shade that drifted cannot be traced to its cause. A color reading needs context. One reading against the target shade shows whether the run is in tolerance, but the same reading can come from an under-dosed colorant at the right hue or an over-dosed colorant at the wrong one. Pairing each reading with the addition percentage at that sample point shows whether the shade moved because the pump drifted or because the colorant lot read differently. Dispersion notes belong in the record too. A short note on whether a sample showed streaks in the base, body, or neck tells the next shift whether a color complaint is a colorant issue or a melting issue, and a photograph kept against the sample ID saves later discussion. The most useful record is specific enough for another engineer to re-run the trial without asking what happened. Record pump settings, sample points, and line conditions instead of a final pass or fail.

Conclusion

Low letdown ratio, precise metering, and actual addition percentage are separate numbers, and a PET preform trial is easier to read when each one is recorded on its own. A low-letdown-ratio liquid colorant gives the plant a shade that develops with less material, but that only pays off when the metering pump holds the ratio steady through the shift and the record shows what the pump delivered. ColorWay Colorants is a liquid colorant manufacturer focused on PET packaging, and our colors are built around low letdown ratio, precise metering and controlled addition, even dispersion, and a liquid format that a preform line can feed. To move from planning to a trial, send your resin grade, shade target, and current metering setup, and we will prepare a sample and trial plan for your line.

FAQ

Q: What does low letdown ratio mean for PET bottle preform coloring?

A: Low letdown ratio means the colorant develops its target shade with less liquid per unit of PET resin. It is a property of the colorant's formulation and dispersion quality, not a pump setting. On a preform line, a lower ratio means less liquid must be fed into the melt to reach the same visual color, which affects material use and the dosing room available to the pump across the shift.

Q: How does precise metering affect color consistency in PET bottle production?

A: Precise metering keeps the actual addition percentage close to plan across a shift, so the shade developed on paper reaches each shot. If the pump drifts, the addition percentage changes without any change to the colorant, and the shade moves with it. A preform line with stable metering helps keep bottle color stable across the run, even when line speed or melt temperature shifts slightly.

Q: Which trial records help a PET plant evaluate liquid colorant dosing?

A: A useful trial record pairs pump output with line throughput for each sample, ties the sample to a resin lot and colorant lot, and notes the addition percentage at that sample point. It also keeps a short dispersion note covering the base, body, and neck, plus a photograph or color reading for each sample. With those layers, a second engineer can re-run the trial and compare results without guessing what happened.

Sources / References

Dye and pigment dispersion background

Polyethylene terephthalate resin background

Related Examples

ColorWay Liquid Colorant for Plastics

Previous
Food-Contact Colorant Paperwork and Sample Trials for PET Bottles
Read More
Next
Liquid Colorant for rPET Bottle Trials and Shade Matching
Read More
Leave a message
First Name*
Last Name*
Email*
Your Country*
Company Name*
Mobile Number
Message*
Thank you for your interest. We greatly value the opportunity to occasionally update you on our products, services, and content that may align with your interests.
To proceed, please tick the checkbox below to continue.
I consent to being contacted by ColorWay Global using the provided information for purposes related to products, services, and other relevant content, including the requested brochure and newsletters.
We care about your privacy and want to protect it. To learn how we handle your data, please read our Privacy Policy.